Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure Integrated

Product Details
Customization: Available
After-sales Service: Factory After Serice by Real Time
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (24)
  • Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure Integrated
  • Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure Integrated
  • Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure Integrated
  • Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure Integrated
  • Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure Integrated
  • Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure Integrated
Find Similar Products

Basic Info.

Model NO.
DN65 temperature and pressure integrated
Application
Industrial Production
Type
Vortex Flow Meter
Measuring Media
Liquid, Gas, Steam (Saturated Steam, Superheated S
Measurement Object
Open Channel
Certification
ISO
Transport Package
Carton
Trademark
AILEIKE
Origin
Jiangsu
HS Code
9026100000
Production Capacity
5000

Packaging & Delivery

Package Size
80.00cm * 60.00cm * 50.00cm
Package Gross Weight
15.000kg
Lead Time
5 days (1 - 5 Pieces)
7 days (6 - 10 Pieces)
15 days (11 - 50 Pieces)
To be negotiated ( > 50 Pieces)

Product Description

Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure IntegratedInstantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure IntegratedInstantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure Integrated
Product Display
01 02 03 04 05
Intelligent
LCD meter head
ABS waterproof
joint
Stainless
steel bellows
Thickened
condenser tube
Flange material
Instantaneous flow,
cumulative flow
Display temperature
and pressure
Built in operatio buttons
Can be set and adjusted in real-time
Effective isolation from the outside world
Steam and water vapor enter
Ensure accurate
measurement
Long service life
Specially made
corrugated pipe
Significant compressive performance
Enhance and prolong the service life
2mm wall thickness
Significant improvement in overall compressive strength
Made of stainless steel material
Good toughness and high temperature
resistance
Long term use is not easy to rust
Product Information
Product name Vortex Flowmeter
Measurement accuracy Level 1.0, Level 1.5  2.5-level plug-in type
Flow range Liquid: 0.35~7.0m/s   Gas: 5.0~60.0m/s   Steam: 6.0~70.0m/s
Measurement medium Liquid, gas, steam(Saturated steam, superheated steam)
Medium temperature Room temperature: -25 ºC to+100 ºC(Above 100 ºC as required)
Table body material 304 stainless steel(Other material agreement ordering)
Medium pressure 16Bar  25Bar 40Bar(≥ 4.0Mpa protocol ordering)
Protection grade Normal type: IP65
Explosion proof grade Intrinsic safety type: iaIICT1-T5
Ambient condition Environmental temperature -25 ºC~+55 ºC  Humidity: 5-90% (RH50 ºC)
Power supply Pulse type 12VDC~+24VDC
Current type 12VDC~+24VDC 4-20mA
Battery powered 3.6V
Output signal Frequency pulse signal 2~3000Hz,
low level ≤ 1V, high level ≥ 5V
Two wire 4-20mA signal explosion-proof
load ≤ 300 Ω
Non explosion proof load ≤ 500 Ω
Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure Integrated
Structural function
1,Pressure 2,Instantaneous flow rate and units
3,Temperature 4,Total quantity and unit
Left shift, parameter setting confirmation key, and exit subdirectories key
Factory settings include shortcut keys, downward movement keys, and decreasing number keys
Up and Down arrow keys
Right shift, enter parameter settings
Selection recommendation
Selection Table Remarks
Enterprise standard ALK                 enterprise standard
code E28A               Liquid
E28B               Gas
E28C               Steam
Nominal Diameter xxxxxx             DN25-2000 optional
Structural style D1           Full pipe flange clamp type
D2           Simple insertion type
D3           Ball valve plug-in type
D4           High voltage type
D5           Anti corrosion type
Compensation method A         No compensation
B         Temperature compensation
C         Pressure compensation
D         Temperature and pressure
compensation
OUTPUT 0       No output
1       Pulse output
2       4~20mA
3       HART
4       RS485
Pressure A     Normal pressure
B     High pressure
Temperature 1   Normal atmospheric
temperature
2   High temperature
Power supply mode A Internal battery power
supply with no output
B 24VDC
C Dual power supply
Flow range
Sensor
Communication
(mm)
Liquid Gas
Measurement
range (m3/h)
Output frequency
range (Hz)
Measurement
range (m3/h)
Output frequency
range (Hz)
15 1.2-6 118-590 4~28 400~2700
20 1.5-10 56-374 6~40 224~1500
25 2~16 41~330 8~50 170~1030
40 2.5~25 12~120 25~180 120~870
50 3.5~40 9~105 35~300 92~735
65 7.5~70 9~83 50~500 59~588
80 12~130 7~80 80~800 50~493
100 18~160 6~49 120~1200 36~370
125 25~250 4 ~ 40 180~1800 30~300
150 50~400 4~38 320~2800 31~270
200 70~700 3~30 560~6000 22~240
250 120~1200 2.5~25 890~8000 18~170
300 200~2000 2.4~24 1360~12000 17~150
(300) 200~1800 11~98 1560~15000 83~830
(400) 350~3000 11~92 2750~27000 83~836
(500) 500~4000 10~79 4300~43000 84~834
(600) 700~5600 9.5~76 6200~61000 83~830
(800) 900~7200 7~55 11000~110000 83~829
(1000) 1300~12000 6.3~56 17000~170000 83~820
>(1000) agreement   agreement  
Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure IntegratedInstallation diagram
Gas installation diagram
When measuring gas, instruments are installed in vertical pipelines with no restrictions on gas flow direction. However, if the pipeline
contains a small amount of liquid,to prevent liquid from entering the instrument measuring tube, the airflow should flow from bottom to top.
Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure IntegratedLiquid installation diagram
When measuring liquids, in order to ensure that the pipeline is filled with liquid, it is necessary to install vertical or inclined pipelines Flow should be ensured from bottom to top. If there is a small amount of gas in the pipeline, the instrument should be installed at a lower position.
Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure Integrated
Installation method
 
1, Shrinking diameter 2,Expanding diameter
3,1 * 90 ºC bent pipe 4,2 * 90 ºC bend in the same plane
5,stop valve 6,2 * 90 ºC bend pipe not in the same plane
7,When a vortex flow sensor is combined with
a pressure sensor and a temperature sensor to
form a measurement system, the location map
of the pressure and temperature measurement
points is shown
 
Matters needing attention
1. Try to avoid strong electrical equipment, high-frequency equipment, and strong switching power supply equipment as much as possible.
2. Avoid direct effects from high-temperature heat sources and radiation sources.
3. Avoid high temperature environments and highly corrosive gas environments.
4. Vortex flowmeter instruments should be avoided from being installed on pipelines with strong vibration as much as possible.
5. Instruments should be installed indoors, and when installed outdoors, attention should be paid to waterproofing, with special attention paid
At the electrical interface, the cable should be bent into a U-shape to prevent water from entering through the cable
Enter the amplifier casing.
6. There should be ample space around the instrument installation point for installation and connection
Line and regular maintenance.
Instantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure IntegratedInstantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure IntegratedInstantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure IntegratedInstantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure IntegratedInstantaneous Flow Intelligent Vortex Flowmeter DN65 Temperature and Pressure Integrated
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier